IKA PETTE fix 100 µl

IKA PETTE fix 100 µl

Lies comfortably in your hand with uncompromising precise performance: The IKA PETTE fix single-channel pipettes are used for many different applications in the modern laboratory. Color-coding simplifies rapid selection of the right pipette. The impact-resistant, UV-resistant and chemically resistant conical tip ensures reliable metering in the long-term.

Improved ergonomics as a result of replaceable handles
IKA pipettes include three interchangeable handles in various different shapes and materials in the delivery. The choice of the right handle for your particular hand means that the pipette can be adapted to suit your individual requirements. This ergonomic optimization permits comfortable and wrist-friendly working, and ensures that the pipette sits in your hand perfectly in daily use for easy grasping of the working points. Precise and repeatable results are thus guaranteed.

Straightforward ejection of the tip of the pipette
After the pipetting process, the tip of the pipette is ejected quickly and without time-consuming hand repositioning simply by pressing the central multifunction button. The round design means that the single-handed ejection works equally for both right-handed and left-handed users.

Robust and smooth
The piston and tip cone are made from DLC-coated stainless steel. DLC stands for diamond like carbon and is a diamond-like type of carbon which exhibits high levels of wear and corrosion resistance, together with particular hardness and low frictional indices. The DLC coating means that the tip cone is particularly insensitive and also ensures that the tips of the pipettes are always in perfect condition and are securely seated, without leaks. The extremely good anti-friction properties of the DLC also mean that the pipette will only need to be re-greased on rare occasions. The benefit of the coating for the user is primarily the consistent and low level of force required when absorbing and discharging the liquid to be pipetted.

Maintenance-friendly, process-secure and easy to clean
Regular cleaning and maintenance of the pipette guarantees a long service life for the product. The volume unit with piston and seal can be replaced completely in just a few hand movements. The equally simple assembly is acknowledged audibly by a click and is thus process-secure.

Simplified acquisition, documentation and monitoring
Acquisition, documentation and monitoring of equipment and processes is of great importance in most laboratories. The serial number of the IKA PETTE can be scanned from a QR Code on the housing, easily and without transfer errors. The serial number and the pipette are thus uniquely linked.

Can be autoclaved at 121°C
The IKA PETTE is ideally suited to heat and high-pressure sterilization. Thanks to its simple construction, the pipette can be cleaned and autoclaved either in complete or in dismantled state.

Large range of pipette tips
All the PETTE fix and vario models are compatible with universal fit pipette tips from most manufacturers. Pipette tips having the standard color codes gray, yellow, and blue always fit on our pipettes, marked accordingly. This means that there is a wide range of pipette tips to choose from and you can rest assured that only suitable tips are fitted.

DesignAir displacement piston-operated pipette
Handlingmechanical
Volumefix
Number of channels1
Colour CodeYellow
Nominal volume100 µl
Accuracy with nominal volume±0.6 µl
Accuracy with nominal volume±0.6 %
Precision with nominal volume±0.2 µl
Precision with nominal volume±0.2 %
Certificate of confirmity according to ISO 8655yes
Autoclavableyes
Piston materialstainless steel DLC coated
Dimensions (W x H x D)30 x 248 x 63 mm
Weight0.085 kg
Permissible ambient temperature5 – 40 °C
Permissible relative humidity90 %

 

Control and monitoring
The intuitive software allows easy control and monitoring of the bioprocess and associated parameters via a 10.4-inch tablet. Users can select from batch, fed-batch, and perfusion/continuous operating modes, catering to various cell culture techniques. The innovative Chaotic Mixing function enables efficient and homogeneous mixing when required. The control software provides clear calibration management, real-time data visualization, and complete process documentation, ensuring compliance with FDA CFR Part 11 requirements (optional).

Gas supply
Precise and adjustable gassing is achieved through four individual built-in mass flow controllers for four each separate gas line (N2, O2, air and CO2), enabling flow rates of 0.01 – 2 L / min. tailored to cell growth requirements. By using the integrated and freely customizable cascade control system, each gas flow can be automatically adjusted by the software at any time according to the ambient conditions in order to maintain the target parameters.

Liquid supply
Four integrated Watson-Marlow pumps with adjustable direction and speed offer highest precision and versatility in pumping in and out acid, base, anti-foam agents and feeding solutions for mammalian cell culture media management.

Sensors
HABITAT Bioreactor comes equipped with latest technology sensors to precisely monitor and control critical bioprocess parameters. The following sensors are included in our standard sales vessel packages:
• pH
• DO (dissolved oxygen)
• temperature
• filling level
• foam
Optional sensors: CO2, Conductivity, Turbidity, Viable cell mass, Redox, Off-gas analysis and more.

PID temperature control
The integrated PID control ensures precise temperature regulation at all times, regardless of vessel type (single-wall or double-wall) or fill level. Single-wall glass vessels can be heated with a heating blanket, allowing for accurate temperature settings above room temperature. With the optional use of a cooling finger, it is also possible to achieve temperatures below room temperature. For double-wall vessels, in combination with an IKA thermostat, the temperature range can be freely adjusted between 5-80°C, independent of room conditions or heat generated by the culture itself.

All features at a glance
• compact, space-saving design, dimensions: 223 x 402 x 450 mm (WxDxH)
• latest technology sensors for better insights and more control
• large screen tablet for easy operation (10.4 inch)
• intuitive, easy-to-use control software that provides simple initial setup and intuitive user assistance throughout the process
• four integrated Watson-Marlow pumps
• high precision motor speed control
• cross platform connectivity: USB, PC, RS232, OPC-UA, ethernet, external signal input, external pump, single-use unit, thermostat
• data storage
• four built-in mass flow controllers for gas supply: N2, O2, air, and CO2
• status LED display: direct error display by indicator light

Note: Only a control tower and the separately available vessel package make up a functional unit.

Scope of delivery

  • HABITAT cell S099
  • Tablet with software for bioreactor
ControllerCell Growth
Operating modetimer, continuous and program operation
DisplayTablet PC
Operationtouch screen
Data memory size32 GB
Auto restart after power failureyes
Ethernet interfaceyes
Single use reactor interfaceyes
Thermostat interfaceyes
Ext. pump interfaceyes
Gravimetric feedingyes
Exponential feedingyes
Biomass feedingyes, with Excell Sensor
OPC UA interfaceyes
Filter heateryes
LED light panelAccessory
Stirring motoryes
Calibration guide temperatureyes
Calibration guide pHyes
Calibration guide pO2yes
pH – temperature compensationyes
Mode hose fillingyes
Stirrer control modeoff, manual, profile, Cascade-pO2 control, chaotic
Speed range1 – 2200 rpm
Speed deviation >= 100 rpm±2 %
Speed deviation <= 100 rpm±5 rpm
Speed displayTFT
Reversible direction of rotationyes
Timeryes
Timer displayTFT
Time setting range1 – 120 min
Heating blanketyes
Heat output250 W
Heat controlTFT
Temperature controlPID
Working temperature5 – 80 °C
Connection for ext. temperature sensorPT1000
Temperature displayyes
Temperature measuring range0 – 100 °C
Temperature measurement resolution0.1 K
Temperature control accuracy±0.2 °C
Temperature limit min.0 °C
Temperature limit max.110 °C
pH measurementyes
pH control modeoff, auto, profile
pH value displayTFT
pH measuring range0 – 14 pH
pH measurement resolution0.01 pH
Accuracy of pH measurement±0.02 pH
Set resolution pH value0.01 pH
pH control accuracy±0.05 pH
Conncetion for pO2 sensoryes
pO2 control modeoff, manual, auto, profile
Measurement range pO2 min.0 %sat
Measurement range pO2 max.200 %sat
Resolution pO2 measurement0.01 %sat
Accuracy of pO2 measurement±0.3 %sat
pO2 control accuracy0.3 %sat
Exhaust Gas Analyzeryes, with Blue Vary Sensor
OUR,CER,RQ calculationyes, with Blue Vary Sensor
RQ feedingyes, with Blue Vary Sensor
Digital pH sensoryes, with EasyFerm Bio Arc Sensor
Measuring Range min. digital pH0 pH
Measuring Range max. digital pH14 pH
Accuracy digital pH±0.02 pH
Digital DO sensoryes, with OxyFerm FDA Arc
Measuring Range min. digital DO0 %sat
Measuring Range max. digital DO200 %sat
Accuracy digital DO±2 %
Optical DO sensoryes, with VisiFerm RS485-ECS
Measuring Range min. optical DO0 %sat
Measuring Range max. optical DO300 %sat
Accuracy optical DO±1 %
Biomass sensoryes, with CGQ BioR Sensor
Measuring Range min. Biomass0.5 OD
Measuring Range max. Biomass50 OD
Digital Redox / ORP sensoryes, with EasyFerm Plus ORP Arc
Measuring Range min. digital ORP-1500 mV
Measuring Range max. digital ORP1500 mV
Digital biomass sensoryes, with Excell Sensor
Measuring Range min. digital biomass0 AU
Measuring Range max. digital biomass6 AU
Accuracy digital biomass±1 %
Viable Cell Density Sensorsyes, with Incyte Sensor
Measuring Range min. cell density5 x 10^5 cells/mL
Measuring Range max. cell density8 x 10^9 cells/mL
Accuracy cell density±1 %
Gas in connection Air6 mm
Gas out connection Air6 mm
Gas in connection O26 mm
Gas out connection O26 mm
Gas in connection N26 mm
Gas out connection N26 mm
Gas in connection CO26 mm
Gas out connection CO26 mm
Aeration modecontinuous & automatic
Display flowratel/min, cc/min
Input pressure200 – 3000 mbar
Pressure out min.200 mbar
Pressure out max.1000 mbar
Flowrate Air min.10 cc/min
Flowrate Air max.2000 cc/min
Flowrate O2 min.10 cc/min
Flowrate O2 max.2000 cc/min
Flowrate N2 min.10 cc/min
Flowrate N2 max.2000 cc/min
Flowrate CO2 min.10 cc/min
Flowrate CO2 max.2000 cc/min
Measuring and control accuracy of the gas control units±2 % fsr
Peristaltic pumpyes
Numbers of pump heads4
Pump head functionAcid, Base, AntiFoam, Level
Pump headWatson Marlow 114DV
Number of pump tubes4
Number of pump rollers4
Flow rate min.0.3 ml/min
Flow rate max.270 ml/min
Flow rate control accuracy±0.3 ml/min
Pump Speed min.33 rpm
Pump Speed max.400 rpm
Pump reversible direction of rotationyes
Pump speed displayTFT
Inner tube diameter min.0.5 mm
Inner tube diameter max.4.8 mm
Tube outer diamter min.4.1 mm
Tube outer diamter max.8.4 mm
Tube materialSilicone
Tube hardness50 – 60 Shore A
Dimensions (W x H x D)224 x 624 x 405 mm
Weight14 kg
Packing unit1 pcs
Permissible ambient temperature5 – 40 °C
Permissible relative humidity80% (up to 31°C), decreasing linearly to max. 50 (@40°C)
Protection class according to DIN EN 60529IP 20
RS 232 interfaceyes
USB interfaceUSB-B
WiFi Interfaceyes
Voltage100 – 240 V
Frequency50/60 Hz
Power input300 W
Power input max.1100 W
Power input standby10 W
Fuse2x T5.0A 250V
Welcom to truegenix lab solution

20

Years of expericence

Laboratory

We Provide Reliable & High- Quality Clinical Service

Welcome to the Labout Rare Chemistry Research Documentation Center, a hub exploration & discovery in the realm of uncommon & extraordinary chemical phenomena.

  • Modify the theming of the prebuilt automation platform
  • Override the default strings for any element
History

Our Journey Map

Welcom to truegenix lab solution
1997

The Beginnings

Choose a suitable location for your laboratory, considering factors such as accessibility, space requirements, and proximity to potential collaborators.

The Beginnings

Winning a research award is a significant achievement and a testament to your hard work, dedication, and contributions to your field of study.

2003
Welcom to truegenix lab solution
Welcom to truegenix lab solution
2008

Opening New Laboratory

Choose a location that meets the specific needs of your research. Consider factors such as proximity to collaborators, accessibility, and availability necessary utilities & infrastructure.

Updating Equipment

Determine the budget required for updating the equipment. Explore funding options, including grants, institutional support, or collaborations with industry partners.

2016
Welcom to truegenix lab solution